This anti-sticking kettle agent is used in the polymerization process of polyvinyl chloride to protect the inner wall of the polymerization kettle and has excellent anti-sticking effect. After spraying, a protective layer is formed on the stainless steel surface. This protective layer can make the material less likely to stick to the kettle.Extend the kettle cleaning cycle, improve equipment utilization, and improve resin quality.

Chat Now
Product Introduction

Features


 

Polyphenolic aldehyde is condensed with special ingredients to better prevent PVC resin from adhering to the kettle wall.

 Add special film-forming components such as chitin to chelate more firmly with the stainless steel kettle wall.

Unique, making the COD remaining in the wall coating liquid after spraying lower.

 

Technical data


 

Solid content

5.5±0.5% (ordinary type)

10.0±0.5% (high content)

PH 

12.5±0.3

Iron ion content

≤5ppm

Viscosity at 25°C

≤10cp

Specific gravity at 20℃

1.02±0.01

freezing point

-1℃

Product description


 

This anti-sticking kettle agent is used in the polymerization process of polyvinyl chloride to protect the inner wall of the polymerization kettle and has excellent anti-sticking effect. After spraying, a protective layer is formed on the surface of stainless steel. This protective layer can make the material less likely to stick to the kettle.

Extend the kettle cleaning cycle, improve equipment utilization, and improve resin quality.

 

Instructions


 

1. First lower the spray valve. After the spray valve rotates for 40 seconds, the steam regulating valve opens, the steam cut-off valve opens, and steam is introduced into the kettle for 50 seconds.

2. After the steam is introduced for 50 seconds, the anti-sticking kettle agent pump starts, the regulating valve opens, the cut-off valve opens, and the coating of the kettle begins. When the amount of coating in the kettle reaches the amount, the anti-sticking kettle agent pump stops and is closed and cut off in sequence.

The valve, regulating valve, and then the upper steam valve are closed in sequence.

3. The bottom valve at the bottom of the kettle is opened (the valve position is opened to the steam position), the lower steam regulating valve is opened, and the steam cut-off valve is opened. At this time, steam is introduced from the bottom of the kettle. After 60 seconds (the temperature in the kettle reaches 70-75°C), close the steam regulating valve, close the steam shut-off valve, and close the bottom valve of the kettle.

4. From the beginning to the end of the coating kettle, the circulating water main and auxiliary valve positions are opened 4%.

 

 In order to ensure the coating effect of the kettle, the spray valve on the kettle must be inspected regularly. (Recommend a cycle of 30 days), check whether the nozzle of the sprinkler pipe is blocked (based on the flow rate difference of the water sprayed by the flow meter).

Intuitive monitoring method: based on the flushing flow rate of the spray valve when it is completely unblocked. If the flow rate drops significantly, it means that the spray valve is blocked and should be inspected.

 

Dosage


 

30 kettle 1.5kg, 45 kettle 2.5kg, 70 kettle 4.0kg, 105 kettle 7.0kg, 127 kettle 8.0kg

 

Storage and packaging


 

Store in a cool and dry place, tightly packed when not in use. This product is packed in 200-liter plastic barrels with a specification of 200Kg/barrel, and can also be customized according to customer requirements.

 

 

 

 